Warning Icon

For other alternatives, please contact us for more information.

0 Alternative products available

PWRT-606-S

  • Available in:
  • North America

HELIAX® Remote Radio Head Power Cable, 6 conductor with shield, 6 AWG (13.29 mm2), one Red and one Black conductors with Green Stripe, one Red and one Black conductor with Blue Stripe, one Red and one Black conductor with Orange Stripe

Find a Partner
Specifications
Finish making your selections or clear them to view relevant specifications.

Product Classification

Regional Availability North America
Portfolio CommScope®
Product Type Power cable
Product Brand HELIAX®
Product Series PWRT
Ordering Note CommScope® non-standard product

General Specifications

Cable Type Power
Conductor Type, singles Stranded
Conductors, quantity 6
Construction Type Discrete power cable | Non-armored
Drain Wire Type Stranded
Ground Wire Type Stranded
Jacket Color Black
Jacket Color, singles Black with co-extruded blue stripe | Black with co-extruded green stripe | Black with co-extruded orange stripe | Red with co-extruded blue stripe | Red with co-extruded green stripe | Red with co-extruded orange stripe
Supported Application Industrial

Dimensions

Diameter Over Conductor, singles, specific 0.1790 in per 19 strands
Diameter Over Dielectric 6.325 mm | 0.249 in
Diameter Over Drain Wire, specific 2.5700 in per 7 strands
Diameter Over Ground Wire 3.759 mm | 0.148 in
Diameter Over Jacket, nominal 23.368 mm | 0.92 in
Diameter Over Jacket, maximum 24.511 mm | 0.965 in
Diameter Over Shield (Braid) 19.177 mm | 0.755 in
Jacket Thickness 2.032 mm | 0.08 in
Conductor Gauge, singles 6 AWG
Drain Wire Gauge 12 AWG
Ground Wire Gauge 8 AWG
Outer Shield (Braid) Gauge 34 AWG

Electrical Specifications

Conductor dc Resistance 1.444 ohms/km | 0.44 ohms/kft
Conductor dc Resistance Note Maximum value based on a standard condition of 20 °C (68 °F)
Safety Voltage Rating 600 V

Material Specifications

Conductor Material Tinned copper
Dielectric Material PVC
Drain Wire Material Tinned copper
Filler Material Polypropylene
Ground Wire Material Tinned copper
Insulation Material, singles PVC
Jacket Material PVC
Outer Shield (Braid) Coverage 65 %
Outer Shield (Braid) Material Tinned copper
Outer Shield (Tape) Material Aluminum/Poly, non-bonded

Environmental Specifications

Operating Temperature -40 °C to +90 °C (-40 °F to +194 °F)
Environmental Space UV resistant for outdoor and/or direct burial installations
Safety Standard NEC Article 336 (Type TC)

Packaging and Weights

Cable weight 1324.466 kg/km | 890 lb/kft

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Product Classification

Regional Availability North America
Portfolio CommScope®
Product Type Power cable
Product Brand HELIAX®
Product Series PWRT
Ordering Note CommScope® non-standard product

General Specifications

Cable Type Power
Conductor Type, singles Stranded
Conductors, quantity 6
Construction Type Discrete power cable | Non-armored
Drain Wire Type Stranded
Ground Wire Type Stranded
Jacket Color Black
Jacket Color, singles Black with co-extruded blue stripe | Black with co-extruded green stripe | Black with co-extruded orange stripe | Red with co-extruded blue stripe | Red with co-extruded green stripe | Red with co-extruded orange stripe
Supported Application Industrial

Dimensions

Diameter Over Conductor, singles, specific 0.1790 in per 19 strands
Diameter Over Dielectric 6.325 mm | 0.249 in
Diameter Over Drain Wire, specific 2.5700 in per 7 strands
Diameter Over Ground Wire 3.759 mm | 0.148 in
Diameter Over Jacket, nominal 23.368 mm | 0.92 in
Diameter Over Jacket, maximum 24.511 mm | 0.965 in
Diameter Over Shield (Braid) 19.177 mm | 0.755 in
Jacket Thickness 2.032 mm | 0.08 in
Conductor Gauge, singles 6 AWG
Drain Wire Gauge 12 AWG
Ground Wire Gauge 8 AWG
Outer Shield (Braid) Gauge 34 AWG

Electrical Specifications

Conductor dc Resistance 1.444 ohms/km | 0.44 ohms/kft
Conductor dc Resistance Note Maximum value based on a standard condition of 20 °C (68 °F)
Safety Voltage Rating 600 V

Material Specifications

Conductor Material Tinned copper
Dielectric Material PVC
Drain Wire Material Tinned copper
Filler Material Polypropylene
Ground Wire Material Tinned copper
Insulation Material, singles PVC
Jacket Material PVC
Outer Shield (Braid) Coverage 65 %
Outer Shield (Braid) Material Tinned copper
Outer Shield (Tape) Material Aluminum/Poly, non-bonded

Environmental Specifications

Operating Temperature -40 °C to +90 °C (-40 °F to +194 °F)
Environmental Space UV resistant for outdoor and/or direct burial installations
Safety Standard NEC Article 336 (Type TC)

Packaging and Weights

Cable weight 1324.466 kg/km | 890 lb/kft

Regulatory Compliance/Certifications

Agency Classification
ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Product Specification

Video

HELIAX® FiberFeed® Video Playlist
HELIAX® FiberFeed® Video Playlist

Product Specification

Video

HELIAX® FiberFeed® Video Playlist
HELIAX® FiberFeed® Video Playlist